Water chamber: Removal - Refitting
F4R
Special tooling required
Mot. 1448
Remote operation pliers for
hose clips.
IMPORTANT
When working in the engine compartment, take
care as the radiator fan(s) may start up unexpect-
edly (risk of being cut).
To avoid any risk of serious burns when the engine
is hot:
- do not open the expansion bottle cap,
- do not drain the cooling system,
- do not open the bleed screw(s).
WARNING
Before the operation, protect the electrical accesso-
ries to prevent any risk of shor t circuiting and pro-
tect the belts to avoid damaging them.
REMOVAL
I - REMOVAL PREPARATION OPERATION
a Position the vehicle on a two-post lift (see Vehicle:
Towing and lifting) (MR 415, 02A, Lifting equip-
ment).
a Remove:
- the engine cover,
- the engine undertray bolts,
- the engine undertray.
a Drain the cooling system (see 19A, Cooling, Cool-
ing system: Draining - Refilling, page 19A-16) .
COOLING
II - OPERATION FOR REMOVAL OF PART
CONCERNED
a Remove the coolant temperature sensor (see 19A,
Cooling, Coolant temperature sensor: Removal -
Refitting, page 19A-167) .
a Remove the clips (1) from the water chamber inlet
and outlet hoses using the tool (Mot. 1448).
a Disconnect the water chamber inlet and outlet hos-
es.
19A-102
19A
123343