Renault Laguna III Manual page 1205

Table of Contents

Advertisement

Oil vapour rebreathing circuit: Operating diagram
K9K
A: Low load
B: Medium and high load
(1)
Cylinder head cover
(2)
Oil vapour breather pipe
(3)
Oil vapour rebreathing valve
(4)
Air inlet duct
(5)
Turbocharger
(6)
Atmospheric pressure
ANTIPOLLUTION
20965
20965-1
14A-4
A: At low load, the vacuum pressure prevailing in the
air inlet duct is below the spring calibration. Large
quantities of oil vapour are sucked back in by the vacu-
um prevailing in the air inlet duct.
B: At medium or high load, the vacuum pressure pre-
vailing in the air inlet duct pulls the valve diaphragm
and small quantities of oil vapour are rebreathed in via
a calibrated opening.