Host Link Serial Interface
6-3-3

Output Format (Host Link)

Output Data
CHECK
Data
Write
Area
word
Data 0
+0
+1
+2
+3
6-3-(14)
When Host link data output is set for a unit, the measurement results are out-
put in order from the smallest output number.
The measurement results are output in BCD code to the Write Area in the Pro-
grammable Controller.
Each time that data is output, the write flags are switched between
"0000" and "1111". The status of these bits can be monitored to see
when data has been written.
After the first measurement, the write flags are cleared to "0000" so
store "1111" in this digit as the initial value before starting
measurements.
Write
Area
15 to 12 11 to 8
word
Write
+0
flags
3
10
digit
+1
Sign
+2
0000
+3
0000: Positive
1111: Negative
• Digital Output Range
-9,999,999.999
measurement
The minimum value of "-9,999,999.999" will be output for measurements
less than -9,999,999.999.
The maximum value of "9,999,999.999" will be output for measurements
greater than 9,999,999.999.
• JG (Judgement) Outputs
The following values are output when JG (Judgement) has been set:
OK: 0
NG: -1
After measurements have been made in Run Mode, the data up through the
last measurement will be output even if the mode is changed to another mode.
The data output will not be interrupted midway.
Example 1
This example shows the data output when the data 0 measurement is
143.250, data 1 is not set, and the data 2 measurement is -6,943.298.
Bits
15 to 12
11 to 8
0000
0000
0000
0001
0000
0000
0000
0010
Bits
7 to 4
3 to 0
0000
0000
0000
2
1
0
10
digit
10
digit
10
digit
6
5
4
10
digit
10
digit
10
digit
-1
-2
-3
10
digit
10
digit
10
digit
9,999,999.999
7 to 4
3 to 0
0000
0000
Write flags (0000)
0100
0011
Four lowest integer digits
0000
0000
Sign and two highest integer digits
0101
0000
Decimal point
Section 6-3
Contents
Write flags
Measurement result
Contents