Normal Serial Interface
6-2-(66)
Data
The following settings are for line conditions (common to cross points, boxes, and mul-
tiple cross points).
Settings
521
Region 0
data
522
523
524
525
526
527
528
529
530
The following settings data is for cross point and multiple cross point measurements.
Settings
531
Region 0
data
532
533
534
535
536
537
538
539
540
541
542
Details
Extracting level
0: Level 1 1: Level 2 2: Level 3
3: Level 4 4: Level 5
Line angle specification
0: OFF
1: ON
Line angle 0 specification
0: OFF
1: ON
Line angle 0 (0 to 359)
Line angle 1 specification
0: OFF
1: ON
Line angle 1 (0 to 359)
Line angle 2 specification
0: OFF
1: ON
Line angle 2 (0 to 359)
Line angle 3 specification
0: OFF
1: ON
Line angle 3 (0 to 359)
Target color
0: Black
1: White
Angle specification
0: OFF
1: ON
Range of angle (0 to 359)
Limits of angle (0 to 99)
Length specification
0: OFF
1: ON
Length 1 (1 to 999)
Length 1 lower limit (0 to 200)
Length 1 upper limit (0 to 200)
Length 2 (1 to 999)
Length 2 lower limit (0 to 200)
Length 2 upper limit (0 to 200)
q
Defined side of
0: Midline of corner
1: Side 1
2: Side 2
Section 6-2