Search Verification and Candidate Levels
2-13-(13)
Select whether or not to perform detailed searches on models at the candidate
level or higher. If model searches are unstable, set search verification to ON
and adjust the candidate level.
Setting item
Selection/
Setting range
Search verifi-
OFF*
cation
ON
Candidate
0 to 99 (60*)
level
The asterisk (*) indicates the default setting.
Details
Performs a detailed search only on the image with
the highest rough correlation within the measure-
ment region.
Performs a detailed search on all images at the can-
didate level or higher within the measurement
region. The measurements are more stable in com-
parison to when search verification is set to OFF.
Processing time, however, will be longer.
Set the correlation value for detailed search target
images. Reduce the correlation level if the model
searches are unstable. A detailed search will be per-
formed on all images above this level in the rough.
This setting item is enabled only when search verifi-
cation is set to ON.