Host Link Serial Interface
Ladder Program
DIFU(13)
00001
00100
CMP(20)
00100
DM0100
#0000
MOV(21)
25506
#0010
DM0100
MOV(21)
25313
DM0106
010
01015
DIFU(13)
00200
DIFD(14)
00201
00200
00201
ANDW(34)
00215
DM0107
#0001
DM0200
25506
ANDW(34)
00215
DM0110
#0001
DM0201
25506
00300
00100
00301
00315
When the external switch (IR
00001) goes from OFF to ON, the
measurement command (0010) is
written to the input command area
if the area was cleared to 0000.
Detects a change in the
status of the data 0 write
flags.
00215
If the first digit of the data 0
judgement result is equal to 1,
IR 00300 is turned ON to
indicate an NG (no good)
result.
00300
If the first digit of the data 1
judgement result is equal to 1,
IR 00301 is turned ON to
indicate an NG (no good)
result.
00301
00315
The NG results for data 0 and
data 1 are ORed and the
result is output to IR 00315.
This result is maintained until
the next measurement.
Section 6-3