Inputting Camera Images
CHECK
Specifying
Points
2-1-(7)
A frame and display cursor will appear where the model was found and the
screen for inputting physical coordinates will be displayed.
Sampling
12. Input the coordinates for the model position (display cursor) and select
End.
Correcting Mistakes
Press the SHIFT+ESC Keys. The previous sampling can be corrected and re-
executed.
The first sampling will be confirmed, and the second screen will be dis-
played.
Sampling
13. Repeat steps 9 to 12 and perform sampling for at least two locations.
Adjust the sampling region so that only the target figure is enclosed.
Once sampling has been completed, a confirmation message will be dis-
played.
14. Select Execute.
The settings will be registered and the screen in (2.) will return.
This function is used to specify and set any point in pixel units.
If the coordinates of the specified position are input, the calibration data is
automatically calculated. Up to 3 points can be specified.
1time(s)
+
X : [ 0.000]
Y : [ 0.000]
End
2time(s)
+
Registering calibration
Parameters.
Execute
Cancel