Omron F250-UME Software Manual page 277

Table of Contents

Advertisement

Detecting Binary Defects
STEP 5: Setting the Judgement Conditions
Judgement conditions
Area
: 2035.000
[
0.000 : 247808.000]
Gravity X : 180.000
[
0.000 : 511.000]
Gravity Y : 250.000
[
0.000 : 483.000]
: Measurement results for the displayed image
Use these values as a reference for setting upper and lower limits.
1.
Select Reference registration.
Region0(Area(var.box))
A cursor will appear at the position of the center of gravity.
Reference registration
ENT:Set
2.
To change the position, use the Up/Down and Right/Left Keys to move
the cursor.
3.
Press the ENT Key.
The setting will be registered and the screen in (1.) will return.
Make settings for the area and center of gravity.
End
Binary
Measurement conditions
Left edge
Upper edge
Right edge
Lower edge
Reference registration
Judgement conditions
Measurement object
251,184
:Move
Range for an OK judgement
Area range (0 to 9,999,999.999)
Range of movement of the measurement object
in the X direction (-9,999.999 to 9,999.999)
Range of movement of the measurement object
in the Y direction (-9,999.999 to 9,999.999)
Section 2-12
Reference position
2-12-(34)

Advertisement