Omron F250-UME Software Manual page 258

Table of Contents

Advertisement

Detecting Binary Defects
STEP 6: Changing Pixel Skipping
2-12-(15)
The Judgement Conditions Settings Screen will be displayed.
Judgement conditions
2.
Change the settings.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
To shorten measurement processing time, change the number of pixels to be
skipped. The greater the skipping setting, the shorter the processing time.
However, the accuracy of the measurement will decrease.
Once the skipping setting has been changed, perform a measurement and
confirm that measurement can be performed correctly.
Skipping X and Skipping Y
Set how many pixels to skip in the measurement region during measurement.
The default setting is 1, which means that all of the measurement region will
be measured.
1.
Select Detailed conditions.
Region0(Gravity and area)
Area
: 2035.000
[
2000.000 : 247808.000]
Gravity X : 180.000
[
0.000 :
511.000]
Gravity Y :
250.000
[
0.000:
483.000]
End
Skipping X
Pixel
Skipping Y
Binary
Measurement conditions
Region
Reference registration
Judgement conditions
Detailed conditions
Clear
Section 2-12