Omron F250-UME Software Manual page 398

Table of Contents

Advertisement

EC Positioning
2-16-3-2
Cross Points
STEP 1: Setting Measurement Conditions
Measurement conditions
Target color
Note 1
Specifying angle
Note 2
Range of angle
Limits of angle
Specifying length
Length 1
Note 3
Limits of length 1
Length 2
Note
2-16-(15)
1.
Select Judgement conditions.
Region0(Circle)
The Judgement Conditions Setting Screen will be displayed.
Judgement conditions
Measurement result for displayed image.
Use as a reference for upper and lower limits.
2.
Set the radius range for an OK circle.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
1
Set mea-
surement
conditions.
Set the conditions for searching for the positioning mark.
:
Black
:
OFF
:
[ 90]
:
[10]
:
OFF
:
[100]
:
[ 80:120]%
:
[ 50]
End
1.
Select whether the color of the positioning mark will be white or black com-
pared to the background. (Black*, white)
The asterisk (*) indicates the default setting.
Measurement conditions
Search region
Radius
Reference registration
Judgement conditions
Clear
Radius
:
72.000
[ 70.000: 75.000]
End
2
3
(As required)
Set
Set search
conditions
region.
for obtaining
lines.
Note 3
Limits of length 2
Note 4
Defined side of
Section 2-16
4
(As required)
Register
reference
position.
: [ 80:120]%
:
Midline of corner

Advertisement

Table of Contents
loading