Omron F250-UME Software Manual page 865

Table of Contents

Advertisement

Normal Serial Interface
Function 2
6-2-2-5
DISPIMG: Display Image
Function 1
CHECK
Function 2
Changes the image display condition to the specified condition.
Input
DISPCOND <Condition code> Delimiter
The condition codes are the same as shown for Function 1 above.
Output
Command executed correctly:
Command not executed correctly:
Example
This example shows how to change the display image to the "Last NG (before
scroll)".
Input
DISPCOND 3 Delimiter
Output OK Delimiter
Reads the memory number containing the image that is currently being dis-
played.
Input
DISPIMG Delimiter
Output
Command executed correctly:
Command not executed correctly:
A value of -1 will be output when "Through," "Freeze," or "Last NG" is being dis-
played.
Example
In this example, the image in memory number 12 is being displayed.
Input
DISPIMG Delimiter
Output 12 Delimiter
OK Delimiter
Changes the display image.
Input
DISPIMG <Memory number> Delimiter
• Set the memory number between -1 and 35.
• When -1 is specified, the display condition set with DISPCOND or in the
Display settings window (for example, "Through," "Freeze," or "Last NG")
will be used.
Output
Command executed correctly:
Command not executed correctly:
OK Delimiter
ER Delimiter
Memory number Delimiter
OK Delimiter
ER Delimiter
OK Delimiter
ER Delimiter
Section 6-2