Omron F250-UME Software Manual page 129

Table of Contents

Advertisement

Binary Position Compensation
CHECK
Judgement conditions
Area
: 2035.000
[
0.000 : 247808.000]
Gravity X : 180.000
[
0.000 : 511.000]
Gravity Y : 250.000
[
0.000 : 483.000]
: Measurement results for the displayed image
Use these values as a reference for setting upper and lower limits.
STEP 6: Changing Pixel Skipping
Position Compensation Judgement Results and Scrolling
OK: Scroll will be performed.
NG: Scroll will not be performed. The overall judgement will be NG, regard-
less of the measurement result.
End
1.
Select Judgement conditions.
Position0(Gravity and area)
The Judgement Conditions Settings Screen will be displayed.
Judgement conditions
2.
Change the settings.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
To shorten measurement processing time, change the number of pixels to be
skipped. The greater the skipping setting, the shorter the processing time.
However, the accuracy of the measurement will decrease.
Once the skipping setting has been changed, perform a measurement and
confirm that measurement can be performed correctly.
Range for an OK judgement
Area range (0 to 9,999,999.999)
Range of movement of the measurement object
in the X direction (-9,999.999 to 9,999.999)
Range of movement of the measurement object
in the Y direction (-9,999.999 to 9,999.999)
Binary
Measurement conditions
Region
Reference registration
Judgement conditions
Detailed conditions
Clear
Area
: 2035.000
[
20.000 : 247808.000]
Gravity X : 180.000
[
0.000 :
511.000]
Gravity Y :
250.000
[
0.000:
483.000]
End
Section 2-5
2-5-(10)

Advertisement