Omron F250-UME Software Manual page 991

Table of Contents

Advertisement

FAQ
I/O
Question
Will the RUN signal be output during scene switching? - The RUN signal will remain ON during scene switch-
Will the RUN signal turn OFF when the ERROR signal
turns ON with Camera or other errors in Run Mode?
Why does the ERR signal turn ON when no error mes-
sage has been displayed?
In what format is data output for "normal" output?
A command to switch the scene group was executed
through the parallel interface when a Memory Card
was not inserted, preventing returning to the previous
scene group. How can this be fixed?
Answer
ing in Run Mode.
- The RUN signal will remain OFF during scene switch-
ing in Monitor Mode.
The RUN signal will remain ON even if the ERROR sig-
nal turns ON.
The ERR signal turns ON when STEP is input while
the BUSY signal is ON.
Select whether or not the ERR signal will turn ON
under SYS/Measurement control. Refer to
.
The ERR signal turns ON when a command input via
parallel interface has not been received correctly.
For example, the switch scene group command was
input but there is no Memory Card mounted in Memory
Card slot 1 so the current scene group data was
unable to be saved. The ERR signal turns ON.
The output format can be changed under the condition
settings for normal data output. It can be set to either
ASCII or binary.
Refer to
Using a Memory Card
Place the Memory Card into slot 1 and execute the
command to switch the scene group again.
Without a Memory Card
Perform the following. In this example, scene group 0 is
returned to.
1. Turn OFF the Save at switch Scn Group setting
under the Operation settings within the System set-
tings.
2. Execute a command to switch to scene group 0
through the parallel interface.
Section 7-3
.
7-(11)

Advertisement

Table of Contents