Omron F250-UME Software Manual page 491

Table of Contents

Advertisement

QUEST Character Verification
2-21-5
Setting Regions
Operational Flow
STEP 1: Selecting Character Extraction Mode
Mode
Mode:
Type of 1st line
Not specifying
Type of 2nd line
Not specifying
End
Auto Extraction
KB-657 6
01.11.07
Fixed region
K B - 6 5 7 6 2
1
Select
character
extract
mode.
There are two character extraction modes: The Auto Extraction Mode, where
characters within the specified region are extracted automatically, and the
Fixed Region Mode, where regions are set with fixed positions for each char-
acter.
Up to 4 regions can be set. Select the extract mode for each region.
Auto extraction
:
Dictionary setting:
Specifying: Numerals are matched only with the
:
numeral dictionary models and letters are matched
only with the alphabet dictionary models.
Not specifying*: Characters are matched against all
dictionary models.
Inspection region
Characters are extracted automatically from this region.
Two lines of up to 20 characters per line can be extracted.
Inspection region
The inspection region is set for each character. Up to 20 characters
can be set.
Verification can be performed to check if a particular character is at
a particular position.
2
3
Set
Set
inspection
character
region.
string.
Section 2-21
2-21-(22)

Advertisement