Circle Position Compensation
CHECK
2-9-(25)
The Detailed Conditions Settings Screen will be displayed.
Detailed conditions
2.
Change the settings.
Refer to page 2-9-(25) for details.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
Skipping Angle
Set the angle to skip between point extractions.
The density of all points on the circumference corresponding to the skipping
angle will be measured. The most suitable value for the radius of the circle that
was drawn will be set automatically.
The larger the setting, the fewer points will be extracted. This will increase pro-
cessing speed, but decrease detection and rotation accuracy. (0.4 to 2.0
(1.0*))
The asterisk (*) indicates the default setting.
If the skipping angle has been changed, it cannot return to the automatically
set values even if the model is re-registered. To automatically set the most
suitable value for the radius after the skipping angle has been changed, clear
the settings first and then re-register the model.
Example for Skipping Angles of 0.6
A total of 600 points are detected on this line.
1 2 3
The density is determined for each point.
Skipping angle
:
[1.0]
Comparing pitch
:
[1]
Necessary element
:
[20]pix
Edge pitch
:
[1](Edge/Defect)
Num. of circle
:
[1]
End
360
(600 points)
Section 2-9
600