Omron F250-UME Software Manual page 265

Table of Contents

Advertisement

Detecting Binary Defects
STEP 5: Setting the Judgement Conditions
Judgement conditions
Area
: 2035.000
[
2000.000 :
247808.000]
Gravity X :
180.000
[
0.000 :
511.000]
Gravity Y :
250.000
[
0.000 :
483.000]
Axis angle :
75.000
[ -180.000 : 180.000]
End
: Measurement results for the displayed image
Use these values as a reference for setting upper and lower limits.
Measurement value
for axis angle:
10.000
2.
To change the position, use the Up/Down and Right/Left Keys to move
the cursor.
3.
Press the ENT Key.
The setting will be registered and the screen in (1.) will return.
Make settings for the area, center of gravity, and axis.
Range for an OK judgement
Area range (0 to 9,999,999.999)
Range of movement of the measurement object
in the X direction (-9,999.999 to 9,999.999)
Range of movement of the measurement object
in the Y direction (-9,999.999 to 9,999.999)
Rotation range of the measurement object (-180.000 to 180.000,
but only values between -90.000 and 90.000 will be output.)
Axis Angle
-10.000
1.
Select Judgement conditions.
Region0(Gravity and axis)
The Judgement Conditions Settings Screen will be displayed.
Judgement conditions
2.
Change the settings.
3.
Select End.
If this range is to be judged OK,
set to -10.000: 10.000.
Binary
Measurement conditions
Region
Reference registration
Judgement conditions
Detailed conditions
Clear
Area
: 2035.000
[
2000.000 : 247808.000]
Gravity X : 180.000
[
0.000 :
511.000]
Gravity Y :
250.000
[
0.000:
483.000]
Axis angle :
75.000
[
-180.000: 180.000]
End
Section 2-12
2-12-(22)

Advertisement

Table of Contents
loading