Omron F250-UME Software Manual page 601

Table of Contents

Advertisement

Label Data
2-26-1
Selecting the Reference Unit Number
CHECK
Select the unit number of the processing item to be referenced. The unit num-
bers for which the following processing items are set will be displayed as
selections.
• Labeling
• Fine matching (Select a unit for which label area is set as the defect
detection method.)
• EC Defect (Select a unit that is set for a labeling inspection region.)
Do not allow units for the following processing items to come between the
label data unit and the unit that is being referenced.
Processing item
Camera image
Switch camera
Processing items for
position compensation
1.
Select Label data.
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
The initial display for Label Data will be displayed.
2.
Select Label unit.
A screen to select the unit number will be displayed.
3.
Select the unit number of the "labeling" processing item from which to get
the date.
Label unit
4.
Select End.
The settings will be registered and the screen in (1.) will return.
Calibration will not be properly performed for the measure-
ment results of the Label Data processing item.
The Label Data processing item will not be able to get the
data from before scrolling.
0.Camera image
1.Labeling
2.Label data
3.
Label unit
Label No.
Judgement conditions
Label unit
: 1
End
Section 2-26