Lot Number OCV 1
2-24-7
Setting Judgement Conditions
Judgement conditions
Similarity level
Differential level :
Density deviation :
End
2-24-(27)
Set the judgement conditions to determine if the first candidate matches a cor-
rect lot number.
Similarity to the first candidate lot number (0 to 100, 60*)
OK if the similarity is equal to or greater than this value.
[ 60]
:
Difference between the similarity of the first and second
[ 10]
candidates (0 to 100, 10*)
[ 10]
OK if the difference is equal to or greater than this value.
If fixed extraction and no zero suppression are used, then this
value is used to determine if the fixed region is blank or not when
the lot number does not require all of the digits. Set the value to 0
if the blank check is not to be performed.
1.
Select Judgement conditions.
The judgement conditions setting screen will be displayed.
Judgement conditions
2.
Make the settings for each item.
3.
Select END.
The settings will be registered and the screen in (1.) will return.
1.Lot-No. OCV1
Measurement image
Extract conditions
Font
Measurement conditions
Reference date
Inspected region
Judgement conditions
Reference number
Similarity level
:
Differential level :
Density deviation :
End
Section 2-24
[ 60]
[ 10]
[ 10]