Omron F250-UME Software Manual page 78

Table of Contents

Advertisement

Inputting Camera Images
2-1-(5)
Gravity:
Specify the binary level so that the reference figure will be white and select
OK.
Binary level
:Move
Auto
The Controller automatically
sets the binary level
Move the cursor to the upper limit or lower limit and use the Left and Right
Keys to change the value.
Right Key:
SHIFT+Right Keys: Increases the value 10 times faster.
Left Key:
SHIFT+Left Keys:
Up and Down Keys: Switches between setting items.
The model will be registered and the screen in (2.) will return.
8.
Select Sampling.
The first Sampling Screen will be displayed.
Sampling region
Sampling
9.
Decide whether or not to change the sampling region.
Lower limit
Upper[255]
Lower[128]
+
Reverse
:Change
Reverse
Reverses black and
white in the display
Increases the lowest digit by one.
Decreases the lowest digit by one.
Decreases the value 10 times faster.
Calibration(Camera0)
Sampling input
Model registration
Specifying point
Sampling
Specifying coordinate axis
Parameter input
Reference parameter
Reference position
+
Section 2-1
Upper limit
Auto
OK
+
1time(s)

Advertisement

Table of Contents
loading

Table of Contents