1-6-3-5
Changing Differential Judgements as Required
1-(50)
The settings screen will be displayed.
Judgement conditions
Refer to page 1-(26) for information on inputting values.
2.
Make the settings for each item.
3.
Select End.
The judgement condition settings will be registered and the screen in (1.)
will return.
Differential judgement values use the basic gradation of the differences
between the model and measurement object images. Differential judgement
values can be set between 1 and 255. Pixels in areas with a difference greater
than the differential judgement value are converted to 1 (white) and all other
pixels are converted to 0 (black). Thus, only the defects are converted to white
pixels and are measured.
The default differential judgement value of 50 is usually sufficient, but change
this value if the defects are not being detected properly.
Model image
Quantity
:
0 [
0:
0]
Area
:
123.152
[
0.000 : 247808.000]
Gravity X
:
100
[
0.000 :
511.000]
Gravity Y
:
100
[
0.000 :
483.000]
End
Inspection image
Overlaid
Pixels in areas with a differential
greater than the differential judgement
value are converted to 1 (white).
All other pixels (no difference to
model) are converted to 0 (black).