QUEST Character Verification
STEP 2: Setting Inspection Regions
2-21-(23)
1.
Select Select region.
1.QUEST OCV
A list of region numbers will be displayed.
2.
Select a region number.
A list of operation selections will be displayed.
3.
Select Mode.
The screen for specifying the mode will be displayed.
Mode
4.
Select the mode.
5.
Select End.
The settings will be registered and the screen in (2.) will return.
When Automatic Extraction Mode Is Selected
Draw one region for extracting characters.
Measurement image
Extract
conditionsconditions
Character conditions
K B - 6 5 7 6 2
Measurement conditions
Select region
0 1 . 1 1. 0 7
Judgement conditions
Refer string
Region0
Region1
Region2
Region3
Mode
Inspected region
Set string
Clear
Mode:
Auto extraction
Type of 1st line
:
Not specifying
:
Type of 2nd line
Not specifying
End
Section 2-21