Normal Serial Interface
6-2-(48)
Circle Position Compensation Data (Settings Data)
Data
Settings
33
Verification
data
0: ON
1: OFF
34
Candidate level (0 to 99)
35
Model correlation judgement value (0 to 100)
36
Center X coordinate (0 to 511)
37
Center Y coordinate (0 to 483)
38
Radius (0 to 232)
39
Model width WX (15 to 67)
40
Model width WY (15 to 466)
41
Model 0
42
43
44
45
Model 1
46
47
48
49
Model 2
50
51
52
53
Model 3
53
55
56
The following settings data is for 1 Model measurement.
Settings
57
Rotation range
data
0: None 1:
4:
45
5: 0
15
6: 0
30
58
Skipping angle
0: 1
6: 15
59
Model 4
60
61
62
63
64
65
66
Details
Search region upper left X (0 to 511)
Search region upper left Y (0 to 483)
Search region lower right X (0 to 511)
Search region lower right Y (0 to 483)
Search region upper left X (0 to 511)
Search region upper left Y (0 to 483)
Search region lower right X (0 to 511)
Search region lower right Y (0 to 483)
Search region upper left X (0 to 511)
Search region upper left Y (0 to 483)
Search region lower right X (0 to 511)
Search region lower right Y (0 to 483)
Search region upper left X (0 to 511)
Search region upper left Y (0 to 483)
Search region lower right X (0 to 511)
Search region lower right Y (0 to 483)
5
2:
15
3:
, 180
15
, 180
30
7: All angles
1: 2
3: 5
4: 6
5: 10
7: 20
8: 30
Model position upper left X (14 to 497)
Model position upper left Y (16 to 467)
Model position lower right X (14 to 497)
Model position lower right Y (16 to 467)
Search position upper left X (0 to 511)
Search position upper left Y (0 to 483)
Search position lower right X (0 to 511)
Search position lower right Y (0 to 483)
Section 6-2