Omron F250-UME Software Manual page 164

Table of Contents

Advertisement

EC Position Compensation
CHECK
Input parameter
Long side
*1
Short side
*2
Length of long side
*3
[ 80:120]%
Length of Short side
*4
[ 80:120]%
*5
Long side distance
[ 80:120]%
*2
*4
CHECK
2-6-(26)
2.
Select Input figure.
The Input Figure Screen will be displayed.
Input figure
3.
Specify the top left and bottom right coordinates of the box.
Up/Down/Left/Right Keys: Move the cursor.
ENT Key:
The settings will be registered and the screen in (1.) will return.
Figures can be input to make settings only for the Long size and Short size of
the box. Use the parameter input screen to make permissible size range and
other detailed settings.
Inputting Parameters
Set the size of the box and the permissible range using parameter input.
If the size of the box is entered using figure input, those parameters will be
reflected under Long size and Short size on the Input Parameter Screen.
:
[100]
[ 50]
:
:
:
:
End
*1
*3
*5
*6
• Increase the Length of long side and Length of short side.
• Increase the Long side distance and Short side distance.
251,365
Confirms the settings.
*6
Short side distance
[ 80:120]%
*7
Line parallelism
Settings Ranges and Default Values*:
*1: 1 to 512
*2: 1 to 484
*3: 1 to 200 (default: 80:120)
*4: 1 to 200 (default: 80:120)
*5: 1 to 200 (default: 80:120)
*6: 1 to 200 (default: 80:120)
*7: Parallelism of long sides and short sides:
1 to 99 (default: 20)
Section 2-6
:
: [20]

Advertisement

Table of Contents
loading

Table of Contents