Omron F250-UME Software Manual page 629

Table of Contents

Advertisement

Calculation
Clearing Expressions
List of Items
Note 1
Unit
Const
Moves the cursor.
Numerals between 0 and 9,999,999.999 can be set.
Note
CHECK
1.
Use the Up and Down Keys to select the number of the expression to be
cleared from the calculation settings list then press the SHIFT + ESC Keys.
4.Calculation
The selections will be displayed.
2.
Select Clear.
A confirmation message will be displayed.
3.
Select Execute.
The expression will be cleared and the screen in (1.) will return.
Note 2
Note 3
ABS
SIN
AND
MOD
COS
OR
MAX
ANGL
NOT
MIN
ATAN
SQRT
DIST
DEL
BS
OK
1.
Unit
Calculations can be performed using the measurement results for the units
set to the scene currently displayed.
If this item is selected, the unit numbers and processing item names will be
displayed. Select the unit number and then select the measurement item
to be used in the calculation from the submenu that is displayed.
The submenus differ depending on the selected unit. Refer to page 2-29-
(9).
Conditions
0 . U2.R00X-U2.R01X
1 .
2 .
3 .
4 .
5 .
6 .
7 .
SFT+ESC:Edit
Copy
Clear
Expression will be cleared.
Execute
Cancel
Sets the expression.
Deletes the items.
DEL: Deletes the item to the right of the cursor.
BS:
Deletes the item to the left of the cursor.
Section 2-29
2-29-(7)

Advertisement

Table of Contents
loading

Table of Contents