Detecting Binary Defects
CHECK
The figure will be registered.
Region
Add
Figure0
End
Once three figures have been drawn,
Add will no longer be displayed.
6.
If additional figures are to be drawn, select Add.
7.
Repeat steps 3 to 5 as necessary to create the desired shape.
8.
After drawing is completed, select End.
The measurement region will be registered and the screen in (1.) will re-
turn.
The center of gravity (marked by an arrow cursor) and the measurement
region will be displayed.
Figures drawn using OR mode are displayed with solid lines and figures drawn
using NOT mode are displayed with dotted lines.
Correcting or Clearing Figures
1.
In the screen for step 5 above, select the figure to be changed or cleared
using the Up and Down Keys and press the ENT Key.
Region
Add
Figure0
Figure1
End
The figure for the figure number selected using the cursor will be displayed
with solid lines. The selections Correct and Clear will be displayed.
Figure 1 (drawn using OR)
Figure 2 (drawn using NOT)
Figure 3 (drawn using OR)
Figure 0
Figure 1
Correct
Clear