Omron F250-UME Software Manual page 25

Table of Contents

Advertisement

Menu Operations
Flowchart Image
0.
Read image from Camera.
1.
Recognize model.
2.
Change measurement
conditions based on product
type.
3.
Inspect product 1 for
defects.
4.
End
The Application Software also has branch control processing items.
Example: Changing Inspection Conditions Based on the Upcoming Product
Start
5.
Inspect product2 for
defects.
6.
End
Product 2
Product 1
Screen Image
0.Scn 0 =SET=
0.Camera image
1.Classification
2.Branch
3.Fine matching
4.End
5.Fine matching
6.End
7.
ENT:Set SFT+ESC:Edit
Section 1-5
1-(17)

Advertisement

Table of Contents
loading

Table of Contents