Omron F250-UME Software Manual page 508

Table of Contents

Advertisement

Rotation Positioning
2-22-1
Changing Measurement Conditions
Setting item
Selections
Rotation range None*
2
5
8
10
15
30
45
60
90
All angles
Skipping angle 1
10
2
15
3
20
5
* 30
6
Accuracy
Precise
Normal*
CHECK
2-22-(3)
Set the search conditions.
The Controller searches using a model that rotates in skipping angle (*2)
increments within the rotation range (*1).
The settings are used for all measurement regions.
Rotation range
Skipping angle
Accuracy
Select the range for
model rotation.
Select the skipping
angle for the model.
The smaller the
angle, the more pre-
cise the search. Pro-
cessing time,
however, will be
longer.
Finds the measurement value in decimal point units. However, the processing
time is longer.
Position X and position Y: Subpixel units
Angle: 0.01
units.
Finds the measurement value in integers.
Position X and position Y: Pixel units
Angle: 1
units.
Coordinates and Rotation Angle Direction
Depending on whether a right-hand or left-hand coordinate system has
been set, the rotation angle direction changes. Check the rotation angle di-
rection before making rotation search settings.
• When Rotation positioning/Coordinate mode/Calibration is set to OFF, the
coordinate system becomes a left-hand system.
• When Rotation positioning/Coordinate mode/Calibration is set to ON, the
coordinate system is determined by the Calibration setting.
Left-handed system
:
None
:
5
:
Normal
End
Details
Example: Rotation range:
Creates a model that rotates 15
-
30
and 30
.
(Coordinate system: Left-hand)
Image
+30°
+15°
Right-handed system
-
+
Section 2-22
*1
*2
30
, Skipping angle: 15
at a time between
−15°
−30°
+
-