Omron F250-UME Software Manual page 51

Table of Contents

Advertisement

Basic Operations
HELP
SeeAlso
The initial screen for fine matching will be displayed.
2.
Select Measurement conditions.
The Measurement Conditions Settings Screen will be displayed.
Measurement conditions
3.
Make the settings for each item.
4.
Select End.
The setting will be registered and the screen in (1.) will return.
Boundary Inspections
Boundary inspections match the boundary areas (areas where the density
changes).
• OFF
This method masks the boundary, excluding it from inspection. This
means that any defects near the boundary will not be detected. The
boundary level sets the number of pixels near the boundary that will be
excluded from the inspection.
See page 1-(53).
Model
1 square = 1 pixel
• ON*
The whole area is inspected and defects near the boundary will be
detected. The processing time, however, will be longer because eroded
and dilated models are matched to prevent inspection mistakes caused by
measurement object displacement. Only defects detected for both models
will be judged as defects. The size of dilation and erosion can be set using
the boundary level.
The asterisk (*) indicates the default setting.
Measurement conditions
Labeling
Model registration
Judgement conditions
Differencial image
Detailed conditions
Coordinate mode
Model reference
Boundary inspection:
ON
Defect inspection :
Labeling
Target
:
Both
End
Inspection image
If the measurement object is
displaced slightly higher, the
boundary will be detected as
differing from the registered
model.
When Boundary inspection is
OFF: The range of pixels set
for the boundary level are
excluded from the
measurement on both sides of
the boundary.
Section 1-6
1-(43)

Advertisement

Table of Contents
loading

Table of Contents