Circle Position Compensation
STEP 3: Setting Search Regions
STEP 4: Setting Judgement Conditions
CHECK
STEP 5: Setting Detailed Conditions
CHECK
A confirmation screen will be displayed.
Model registration
ENT:Register ESC:Cancel
10. Check that an appropriate position has been registered as the model.
11. Press the ENT Key.
The settings will be registered and the screen in (1.) will return.
Set the search region for each model.
The settings method is the same as for Not Rotate. Refer to page 2-9-(6).
Set the conditions for judging the correlation of the measurement object to the
model. The judgement conditions will be shared by all 4 models.
Set the range between 0 and 100, with 100 for objects that perfectly match the
model. If the correlation is equal to or above the judgement condition set here,
the judgement result will be OK.
Position Compensation Judgement Results and Scrolling
OK: Scroll will be performed.
NG: Scroll will not be performed. The overall judgement will be NG, regardless
of the measurement result.
The settings method is the same as for Not Rotate. Refer to page 2-9-(7).
Adjust the detailed conditions if detection of the rotation positioning tag is
unstable.
Re-register the model if the detailed conditions have been changed.
1.
Select Detailed conditions.
Position(Circular angle)
Measurement
conditions
Model registration
Search region
Judgement conditions
Detailed conditions