Omron F250-UME Software Manual page 499

Table of Contents

Advertisement

QUEST Character Verification
2-21-6
Setting Judgement Conditions
Common Judgement Conditions
Common judgement
Similarity level
Differential level
Set the conditions for judging the 1st candidate character.
There are two types of judgement conditions: Common judgement and individ-
ual judgement. In normal circumstances, adjust the common judgement condi-
tions. Set the individual judgement conditions to perform strict or lenient
judgement for a particular character.
Use this function to set common judgement conditions for all models.
:
[ 60]
:
[ 10]
End
1.
Select Judgement conditions.
1.QUEST OCV
The screen for selecting common or individual judgement will be displayed.
2.
Select Common judgement.
The Common Judgement Settings Screen will be displayed.
Common judgement
3.
Set the conditions.
4.
Select End.
The settings will be registered and the screen in (1.) will return.
OK value (OK if at or above this value)
Similarity level for 1st candidate (0 to 100 (60*))
Difference level between 1st and 2nd candidates
(0 to 100 (10*))
Measurement image
Extract conditions
Character conditions
K B - 6 5 7 6 2
Measurement conditions
Select region
0 1 . 1 1. 0 7
Judgement conditions
Refer string
Common judgement
Individual judgement
Similarity level
:
[ 60]
Differential level
:
[ 10]
End