Omron F250-UME Software Manual page 907

Table of Contents

Advertisement

Normal Serial Interface
Data
Settings
205
Region 0
data
206
207
208
209
210
211
212
213
214
215
216
The following settings data is for defect (deviation) measurement.
217
Region 0
The following data is for the defect (line) inspection region.
Settings
218
Region 0
data
219
220
221
222
The following data is for the defect (circumference) inspection region.
Settings
223
data
224
225
226
The following data is for the defect (arc) inspection region.
Settings
227
data
228
229
230
231
232
Details
Edge detection direction (right edge)
0:
1:
2:
3:
Edge color (right edge)
0: Light
dark
1: Dark
light
Edge level (right edge) (0 to 100)
Noise level (right edge) (0 to 255)
Noise width (right edge) (0 to 255)
Offset width (right edge) (-511 to 511)
Edge detection direction (lower edge)
0:
1:
2:
3:
Edge color (lower edge)
0: Light
dark
1: Dark
light
Edge level (lower edge) (0 to 100)
Noise level (lower edge) (0 to 255)
Noise width (lower edge) (0 to 255)
Offset width (lower edge) (-511 to 511)
Defect judgement (0 to 127)
Start X (0 to 511)
Start Y (0 to 483)
End X (0 to 511)
End Y (0 to 483)
Width (1 to 64)
Center X (0 to 511)
Center Y (0 to 483)
Radius (1 to 512)
Width (1 to 64)
Center X (0 to 511)
Center Y (0 to 483)
Radius (1 to 512)
Width (1 to 64)
Start angle (-180.000 to 180.000)
End angle (-180.000 to 180.000)
Section 6-2