Omron F250-UME Software Manual page 615

Table of Contents

Advertisement

Edge Pitch
2-27-7
Measurement Screens
SeeAlso
CHECK
Detailed measurement values can be displayed on the screen in Monitor and
Run modes. These values are useful when adjusting measurement conditions.
This section describes what kind of information can be displayed for edge
pitch.
Refer to
Run modes.
Press the SHIFT+ESC Keys on the Run Screen to access the following screen
and change Display results to Details.
0.Scn 0
Use the Up or Down Key to change to the unit for which edge pitch is set and
the following detailed screens will be displayed.
0.Scn 0
RUN
1. Edge pitch
Judge
: OK
Number of edges : 5
Average pitch
: 10.000
Average width
: 7.050
RUN
NG
Image status
:
Freeze(Before scroll)
Display image
:Image0
Image size
:
All
Display results
:
Details
End
Image 0 Freeze
OK 45ms
Judgement result for this Unit
Display is inverted for NG.
The measurement region is displayed
in the OK color for an OK judgement;
in the NG color for an NG judgement.