Lot Number OCV 1
SeeAlso
CHECK
2-24-(11)
• If without exception the dot gap is larger than the gap between numbers,
set even extraction.
In the following descriptions, the asterisk (*) indicates the default setting.
Extract Methods
Gap Search*
Finds the gap between numbers and extracts the numbers.
Select this method for most applications.
Gap between numbers
Dilate Extraction
With dot numbers, the gap search may not extract correctly if the gap between
dots is greater than the gap between numbers. In such cases, select dilation
extraction. The numbers are dilated, the dot gaps joined, and then the num-
bers are extracted.
Set the number of dilations under Extract conditions/Dilate level.
Refer to
Use in conjunction with forced extraction because the gap between numbers
are also joined when the numbers are dilated.
Dot gap
Gap between
numbers
Dot gap
Gap between
numbers
Extracted numbers
Numbers dilated, dots joined,
and numbers extracted.