Pattern
2-20-5
Measurement Screens
SeeAlso
CHECK
Measurement Region and Position Display
0.Scn 0
RUN
1.Pattern
Judge :
NG
2-20-(15)
Detailed measurement values can be displayed on the screen in Monitor and
Run modes. These values are useful when adjusting measurement conditions.
This section describes what kind of information can be displayed for pattern
inspections.
Refer to
Run modes.
Press the SHIFT+ESC Keys on the Run Screen to access the following screen
and change Display results to Details.
0.Scn 0
Use the Up or Down Key to change to the unit for which pattern inspection is
set and the following detailed screens will be displayed.
Use the SHIFT+Right or Left Keys to switch in order between the two
screens.
NG
45ms
0
+
+ +
Region number
RUN
Image status
:
Freeze(Before scroll)
Display image
:Image0
Image size
:
All
Display results
:
Details
End
The judgement result for this unit.
Inspection region displayed in OK color for OK
result and displayed in NG color for NG result.
(Figures drawn in OR mode are displayed in solid
lines and figures drawn in NOT mode are displayed
in dotted lines.)
Search coordinates
Position at or above candidate level. Displayed
only when search verification set to ON.
Section 2-20
for details on Monitor and
NG
67ms