Normal Serial Interface
6-2-(100)
Display Measure (Measurement Data)
Data
Measure-
0
Measurement value
ment
data
Display Measure (Settings Data)
Data
Settings
32
Font size
data
0: Small
1: Normal
2: Large
33
Display digit position (0 to 63)
34
Display line position (0 to 23)
35
Reverse display
0: OFF
1: ON
36
Display color
0: Normal color
1: OK color
2: NG color
37
Integer digits (0 to 8)
38
Decimal digits (0 to 3)
Display Judge (Measurement Data)
Data
Measure-
0
Display judgement
ment
-1: NG
data
0: OK
1
Measurement
Display Judge (Settings Data)
Data
Settings
32
Font size
data
0: Small
1: Normal
2: Large
33
Display digit position (0 to 63)
34
Display line position (0 to 23)
35
OK reverse display
0: OFF
1: ON
36
NG reverse display
0: OFF
1: ON
37
Judgement upper limit (-9,999,999.999 to 9,999,999.999)
38
Judgement lower limit (-9,999,999.999 to 9,999,999.999)