Omron F250-UME Software Manual page 134

Table of Contents

Advertisement

Binary Position Compensation
Measurement value
for axis angle:
10.000
STEP 5: Changing Pixel Skipping
SeeAlso
Changing to Gravity and Area (Clearing)
SeeAlso
2-5-(15)
Axis Angle
-10.000
1.
Select Judgement conditions.
Position0(Gravity and axis)
The Judgement Conditions Settings Screen will be displayed.
Judgement conditions
2.
Change the settings.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
To shorten measurement processing time, change the number of pixels to be
skipped. The greater the skipping setting, the shorter the processing time.
However, the accuracy of the measurement will decrease.
Once the skipping setting has been changed, perform a measurement and
confirm that measurement can be performed correctly.
The settings method is the same as for Gravity and area.
Refer to page 2-5-(10).
Clear the settings before changing to Gravity and area.
The settings method is the same as for Gravity and area.
Refer to page 2-5-(11).
If this range is to be judged OK,
set to -10.000: 10.000.
Binary
Region
Reference registration
Judgement conditions
Detailed
conditions
Clear
Area
: 2035.000
[
0.000 : 247808.000]
Gravity X : 180.000
[
0.000 :
511.000]
Gravity Y :
250.000
[
0.000:
483.000]
Axis angle :
75.000
[
0.000: 180.000]
End