Omron F250-UME Software Manual page 200

Table of Contents

Advertisement

Model Position Compensation
2-8-4
Setting Detailed Conditions
Detailed conditions
Verification
Candidate level
If Verification is set to ON, the following two levels of search processing will be executed.
For rough searches, set the reference level for searching for the model. (0 to 99 (60*))
1 Rough Search
Using a rough search model, the Controller
searches for images with a correlation
equal to or greater than the candidate level.
Search
Rough search model
CHECK
2-8-(12)
Change the detailed conditions if the detection of the registered model is
unstable. Once the settings have been changed, check that actual measure-
ment is performed correctly.
:
OFF
:
[ 60]
End
Area with correlation greater
than candidate level.
The size of the model that can be registered depends on whether or not
search verification is selected.
No search verification (default):15
With search verification:No limit
1.
Select Detailed conditions.
1.Model pos. comp
Measurement conditions
Positions compensation 0
Positions compensation 1
Direction
Detailed conditions
Select whether or not to perform further detailed
verification near the position where the model
was found. (OFF*, ON)
2 Detailed Search
The Controller uses a detailed search model and
re-measures the images near the area that was
equal to or greater than the candidate level.
Search
Detailed search model
9 to 70
66 pixels
Section 2-8

Advertisement

Table of Contents
loading

Table of Contents