Model Position Compensation
2-8-2
Setting Position Displacement Compensation Regions
2-8-2-1
STEP 1: Registering the Model
CHECK
Register an image pattern (called a model) in advance. The part of an input
image that is most similar to the model is found, the position is calculated in
pixel units, and the degree of similarity is expressed with a correlation value.
Perform processing directly on the density image taken by the Camera.
1
Register a
model.
Register a characteristic portion as the model for position displacement com-
pensation.
When a model is registered, the center position of the model is registered as
the search coordinates. This position becomes the reference position, so
make sure the measurement object is in the correct position before registering
the model.
The size of the model that can be registered depends on the search verifica-
tion setting under Detailed conditions.
No search verification (default): 15
With search verification: No limit
To register large models, change the detailed conditions before registering the
model. Refer to page 2-8-(12).
1.
Select Position compensation 0 or Position compensation 1.
1.Model pos. comp
The setting selections will be displayed.
2.
Select Model registration.
3
2
Set the
Set the
search
judgement
region.
conditions.
9 to 70
Measurement conditions
Positions compensation 0
Positions compensation 1
Direction
Detailed conditions
Model registration
Search region
Judgement conditions
Model reference
Clear
Section 2-8
(As required)
4
Reference
the model.
66 pixels
2-8-(5)