Using BUSY Signals
STEP in Measure
Note *The asterisk (*) indicates the default setting.
SeeAlso
5-(32)
Measurement will not be performed by the Controller during another measure-
ment, even if the STEP signal turns ON. Set whether or not the ERR signal will
turn ON to notify the external device that the STEP signal was not accepted.
Selection
ERR ON* (See note.) Measurement will not be performed and the ERR signal will
turn ON if the STEP signal turns ON during processing. The
ERR signal will turn OFF when the next STEP signal is input at
the correct timing.
OFF
The ERR signal will not turn ON even if the STEP signal turns
ON during processing. Measurement will not be performed.
1.
Enter System mode and select Measurement control.
Refer to
The Measurement Control Settings Screen will be displayed.
Measurement control
2.
Change the STEP in measure and BUSY range settings.
3.
Select End.
The settings are registered and the System Mode Screen will return.
Details
.
Image storage
:
STEP in measure
:
ERR ON
BUSY range
: Measurement
End