Parallel Interface
Item
Gate ON delay
Gate ON time
(Effective only when
output control is set to
None or Sync.output.)
Timeout
(Effective only when
handshaking is used.)
Num. of delays
(Effective only with
Sync. output.)
Settings
Set the time from when the result is output to the paral-
lel interface to when the GATE signal is turned ON. This
time is used to wait until the data output becomes sta-
ble. Set a time between 1.0 and 1,000 ms that is longer
than the external device's delay time. The default set-
ting is 1.0 ms.
Set the length of time that the GATE signal remains ON.
Set a value between 1.0 and 1,000 ms so that the
external device can read the measurement result. The
default setting is 5.0 ms.
A timeout error will occur if there is no response from
the external device within the timeout time. Set a value
between 0.5 and 120.0 s. The default setting at 10.0 s.
Set the number of times the STEP signal turning ON
will be ignored from the time the STEP signal first turns
ON until that measurement result is output.
Section 6-1
6-1-(4)