Normal Serial Interface
Data
The following settings data is for defect (circle) and defect (arc) measurement.
Settings
67
Defect color
data
0: White
1: Black
2: White and black
68
Element size (4 to 80)
69
Comparing pitch (1 to 6)
70
Defect circle radius (20 to 242)
71
Defect circle width (3 to 39)
The following settings data is for defect (arc) measurement.
72
Start angle (arc) (-180.000 to 180.000)
73
End angle (arc) (-180.000 to 180.000)
The following settings data is for circular angle measurement.
Settings
74
Mode
data
0: Black 1: White 2: Black defect 3: White defect
4: Edge
75
Circle 0 radius (circumference) (20 to 242)
76
Circle 1 radius (circumference) (20 to 242)
77
Skipping angle (0.4 to 2.0)
78
Comparing pitch (1 to 9)
79
Necessary number of elements (1 to 99)
80
Edge pitch (1 to 9)
81
Number of circles (1 or 2)
Scroll (Measurement Data)
Data
Measure-
0
Judgement result
ment
-2: Not measured.
data
-1: NG
0: OK
1
Scroll X
2
Scroll Y
q
3
Scroll
4
Measurement X
5
Measurement Y
6
Measurement angle
7
Reference X
8
Reference Y
9
Reference angle
Scroll (Measurement Data)
Data
Settings
32
Scroll X
data
33
34
Scroll Y
35
q
36
Scroll
37
Details
Details
-
Judgement upper limit (
1,024 to 1,024)
-
Judgement lower limit (
1,024 to 1,024)
-
Judgement upper limit (
1,024 to 1,024)
-
Judgement lower limit (
1,024 to 1,024)
-
Judgement upper limit (
180.00 to 180.00)
-
Judgement lower limit (
180.00 to 180.00)