Display Measurement - Omron F250-UME Software Manual

Table of Contents

Advertisement

Display Measurement

2-44
Display Measurement
CHECK
CHECK
Operational Flow
STEP 1: Setting Measurement Conditions
The Display Measurement processing item is used to display any measure-
ment data on the screen in Run and Monitor Modes.
The display is set using expressions so the calculation results of expressions
using region measurement values or measurement values can be displayed.
Example: Displaying Measurement Values in Combination with Display String
0.Scn 0
RUN
Difference from reference: 20
Use this processing item to display any measurement data on the screens in
Run and Monitor Modes. The display is set using expression, so region mea-
surements or calculations using measurement values can be displayed.
The data set here will be enabled when None or Positions are selected under
System/Display/Display settings/Display results.
Even when the display image is set to be displayed as a reduced image, the
characters will always be displayed in the specified position.
STEP 1
Set
measurement
data.
Use expressions to set the measurement data to be displayed.
1.
Select Display measure.
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
Measurement details
OK 45ms
Image 0 freeze
STEP 2
Set display
conditions.
0.Camera image
1.Binary pos. comp
2.Edge position
3.Calculation
4.Display measure
5.
Section 2-44
Measurement value
STEP 3
Set display
position.
2-44-(1)

Advertisement

Table of Contents
loading

Table of Contents