Normal Serial Interface
Outputting Binary Data
SeeAlso
Data Format
Condition Settings
CHECK
SeeAlso
CHECK
6-2-(106)
The measurement data is multiplied by 1,000 and then output consecutively
using four bytes for each data element. Negative numbers are output as 2's
complements.
Refer to 2's complements in
<Data 1
<Data 0
1,000>
4 bytes
Item
Output format
Digits of integer
Digits of decimal
Minus
Field separator
Record separator
0 Suppress
Example
This example shows an example data output when data 0 is 256.324 and data
1 is -1.000.
$00
$03
$E9
$44
Data 0: 256324
(256.324
1,000)
Unlike ASCII, no field or record separators are output to separate the data for
binary output
Refer to
• Digital Output Range
-2,147,483.648
measurement
The minimum value of "-2,147,483.648" will be output for measurements
less than -2,147,483.648.
The maximum value of "2,147,483.647" will be output for measurements
greater than 2,147,483.647.
• JG (Judgement) Outputs
The following values are output when JG (Judgement) has been set:
OK: 0
NG: -1000 (-1
1,000)
After measurements have been made in Run Mode, the data up through the
last measurement will be output even if the mode is changed to another mode.
The data output will not be interrupted midway.
.
1,000>
<Data 7
œ œ œ
4 bytes
4 bytes
Binary
Setting these conditions is not required. They
are for ASCII output only.
$FF $FF
$FC $18
Data 1: -1000
(-1.000
1,000)
.
2,147,483.647
Section 6-2
1,000>