Inputting Camera Images
2-1-6
Frame/Field
CHECK
Frame/Field is used to select the unit for one image.
Selection
Frame*
Measures using frame images.
Field
Measures images in fields. The processing time can be reduced
but the accuracy of the measurement will be reduced because
the measurement is performed on an image with low resolution in
the vertical direction.
The asterisk (*) indicates the default setting.
This setting can only be made once for each scene. If Camera image is set for
more than one unit, the Frame/Field menu will be displayed under Camera
image only for the unit with the lowest number.
Field images
Even
Resolution: 512 × 242 (H × V)
Frame image
Resolution: 512 × 484 (H × V)
1.
Select Frame/Field.
0.Camera image
Odd
Resolution: 512 × 242 (H × V)
One frame image is created when
two field images are combined.
Camera settings
Select camera
Filtering order(Image0)
Filtering(Image0)
BGS levels(Image0)
Filtering order(Image1)
Filtering(Image1)
BGS levels(Image1)
Frame/Field
Section 2-1
Details
Images showing alternate fields