Parallel Interface

Output Format

Signal
OR
Outputs the overall judgement result.
DO0 to DO31
DO Judgement Output
The judgement results for expressions 0 to 31 set using the results output processing item DO
judge will be output to DO0 to DO31. (DO0 to DO15 will be output to connector 0 and DO16 to
DO31 will be output to connector 1.)
Refer to
DO Data Output
The measurement values set to expressions 0 to 31 set using the results output processing item
DO data will be output.
Refer to
Only the integer values will be output. Decimal values will be rounded off.
The value range that can be output is -9,999,999 to 9,999,999.
The output for measurement values less than -9,999,999 will be -9,999,999.
The output for measurement values greater than 9,999,999 will be 9,999,999.
Select either 2's complement binary format or BCD format.
Refer to
Output Order
The measurement results will be output in order from the smallest unit number.
Example: DO judge set for unit 5 and DO data set for unit 8
BUSY
DO
CHECK
SeeAlso
CHECK
6-1-(7)
Measurement results are output each time a measurement is made. Data is
output only when the Controller is in Run Mode; data is not output when the
Controller is in Monitor Mode. The user can select whether a signal is output
when the judgement result is OK or when it is NG. The default setting is for a
signal to be output when the judgement result is NG. Refer to
.
.
for a definition of "2's complement"
STEP input
OFF
ON
Measuring
Judge 0
to 31
Unit 5 result
After measurements have been made in Run Mode, the data that is output to
the OR and DO signals is retained until new measurements are made in Run
Mode. The status of these output is retained even if the Controller is switched
from Run Mode to another Mode.
Output signals will return to OFF if TOOL/Clear measurement is executed.
Refer to
The initial value for output signals is OFF, but the signals may go ON about 0.5
seconds after the power is turned ON. Take any necessary precautions when
these signals are read by externals devices.
for details.
Output function
Data 0
Data 2
Unit 8 results
.
Section 6-1