QUEST Character Verification
KB-65767
01.11.07
Extracting region
KB-65767
01.11.07
Extracting region
2-21-(13)
In the following descriptions, the asterisk (*) indicates the default setting.
End Images
Select whether to leave or remove the area adjacent to the extracting region.
(Leave*, Erase (horizontal), Erase (vertical))
For Measurement Objects that Move Vertically
Select Erase (vertical).
If edge has shifted downwards
For Measurement Objects that Move Horizontally
Select Erase (horizontal).
For Measurement Objects That May Move Vertically or Horizontally
Only edges that overlap either vertically or horizontally can be removed. If the
edges overlap both vertically and horizontally, the characters cannot be
extracted correctly. If the possibility exists of overlap in both directions, adjust
the position and size of the extracting region so that only the characters to be
extracted fall within the extracting region.
Incorrect
KB-65767
01.11.07
Edge section that overlaps
extraction region is removed
before extraction executed.
KB-65767
01.11.07
If the edge has shifted to the right
KB-65767
01.11.07
Edge section that overlaps
extracting region is removed
before extraction executed.
Correct
Section 2-21
Adjust size of extracting region.