Omron F250-UME Software Manual page 75

Table of Contents

Advertisement

Inputting Camera Images
2-1-1
Camera Settings
2-1-1-1
Shutter Speed
2-1-1-2
Lighting Control
2-1-1-3
Calibration
HELP
CHECK
Sampling
Change the shutter speed when the object is moving quickly, causing the
image to be blurred.
The shutter speed can be changed from the menu for F150-S1A and F160-S1
Cameras only.
Refer to
speed operations.
When using Cameras with Intelligent Lighting, the light level can be adjusted
from the Controller.
Refer to
control operations.
Calibration can be set to output the measurement results in physical units.
There are four settings for calibration: Sampling, Specifying point, Specifying
coordinate axis, and Parameter input.
Refer to
To output measurement results in physical units, set Coordinate mode/Calibra-
tion to ON for each processing item.
If Calibration remains set to OFF, the default settings will remain, and mea-
surements using the Camera coordinates will be output.
The sampling function is used to set calibration based on measurement
results. Register a model, and perform a sample measurement to obtain the
position. (The position will be obtained in sub-pixel units.) Enter the physical
coordinates of the position of the model. The calibration will be calculated
automatically. Sample measurements can be made in up to 3 places.
• When the magnifications are the same for the X and the Y directions,
make sample measurements in 2 places only.
• When the magnifications in the X and Y directions are different, perform
sampling measurement in 3 places.
for information on calibration.
Section 2-1
for information on shutter
for information on lighting
2-1-(2)

Advertisement

Table of Contents
loading

Table of Contents