Omron F250-UME Software Manual page 175

Table of Contents

Advertisement

EC Position Compensation
2-6-5
Measurement Screens
SeeAlso
CHECK
Scroll Amount
Detailed Display
Detailed measurement values can be displayed on the screen in Monitor and
Run modes. These values are useful when adjusting measurement conditions.
This section describes what kind of information can be displayed for EC posi-
tion compensation.
Refer to
Run modes.
Press the SHIFT+ESC Keys on the Run Screen to access the following screen
and change Display results to Details.
0.Scn 0
Use the Up or Down Key to change to the unit for which EC position compen-
sation is set and the following detailed screens will be displayed.
Use the SHIFT+Right or Left Keys to switch in order between the four
screens.
0.Scn 0
RUN
1.EC pos. comp
0
Judge:OK
ScrollX:256.321
ScrollY:269.213
Scroll : 20.0
The measurement results for each region will be displayed.
0.Scn 0
RUN
1.EC pos. comp
0
Region0
Pos.X
295.667
Pos.Y
315.675
Angle
RUN
Image status
:
Freeze(Before scroll)
Display image
: Image0
Image size
:
Display results
:
Details
End
OK 45ms
0.
OK 45ms
Region1
0.000
Section 2-6
for details on Monitor and
All
Region number
Search region
Output coordinates
2-6-(37)