Omron F250-UME Software Manual page 256

Table of Contents

Advertisement

Detecting Binary Defects
STEP 4: Re-registering Reference Values
CHECK
CHECK
2-12-(13)
2.
Select either Correct or Clear and press the ENT Key.
If Correct is selected, the cursor will be displayed. Correct the size and po-
sition of the figure as desired.
If Clear is selected, the selected figure will be cleared.
This operation is performed when only the reference values are to be re-regis-
tered.
When a measurement region is drawn, the measurement is performed for the
displayed image and the results are registered as the reference values. If the
re-registering function explained here is used, only the reference values for the
image currently displayed will be registered. The area and center of gravity are
registered for the reference values.
Reference positions can also be changed, facilitating the following application.
Inspecting Positions from a Specified Point
Once the reference values (area and center of gravity) have been obtained for
the image currently displayed, the reference position is changed to an suitable
point. Position inspection can be performed by calculating the difference
between this reference position and the measurement position.
Reference position
changed to suitable point
When the measurement region is changed, the reference values return to the
default settings.
1.
Select Reference registration.
Region0(Gravity and area)
Measurement position (gravity)
Binary
Measurement conditions
Region
Reference registration
Judgement conditions
Detailed conditions
Clear
Section 2-12