Binary Position Compensation
STEP 1: Setting the Binary Level
Set the level for converting 256-gradation images into binary images. Mea-
surements are performed for the white pixels. Therefore, make the settings so
that the measurement object is white.
1.
Select either Position compensation 0 or Position compensation 1.
1.Binary pos. comp
The screen for selecting the detection method will be displayed.
2.
Select Gravity and area.
The selections will be displayed.
3.
Select Binary.
The settings screen for binary levels will be displayed.
Binary level
:Move
Auto
The Controller
automatically sets
the binary level.
Measurement image
Position compensation 0
Position compensation 1
Direction
Gravity and area
Gravity and axis
Binary
Measurement conditions
Region
Reference registration
Judgement conditions
Detailed conditions
Clear
Lower limit
Upper[255]
Lower[128]
Reverse
:Change
Reverse
Reverses dark and clear
in the display.
Section 2-5
Upper limit
Auto
OK
2-5-(4)

Advertisement